Elastomer Couplings EK Servomax® and TX Ecolight®

Please select a Product:

Jaw Couplings / Elastomer Coupling: Faktors and sizing calculations

Temperature factor S
Temperature () Sh 98 A Sh 64 D Sh 80 A
> -30° to -10° 1,5 1,7 1,4
> -10° to +30° 1,0 1,0 1,0
> +30° to +40° 1,2 1,1 1,3
> +40° to +60° 1,4 1,3 1,5
> +60° to +80° 1,7 1,5 1,8
> +80° to +100° 2,0 1,8 2,1
> +100° to +120° 2,4
Start factor SZ
Zh up to 120 up to 240 above 240
SZ 1,0 1,3 on request
Shock- oder load factor SA
Uniform load     SA = 1,0
Non-uniform load
    SA = 1,8
High dynamics, frequent reversing loads     SA = 2,5


Wording:

TKN   =   Rated torque of the coupling (Nm)
TKmax   =   Max. torque of the coupling (Nm)
TS   =   Existing peak torque of the coupling (Nm)
TAS   =   Peak torque of the drive element (Nm)
TAN   =   Rated torque of the drive element (Nm)
TLN   =   Rated torque of the driven element (Nm)
PLN   =   Power of the driven element (KW)
n   =   Speed (rpm)
JA   =   Motor´s moment of inertia (kgm2)
JL   =   Machine´s moment of inertia (kgm2) (Spindle + slide + workpiece)
J1   =   Moment of inertia of a coupling half at the driving end (kgm2)
J2   =   Moment of inertia of a coupling half at the driven end (kgm2)
m   =   Ratio of the moments of inerta driving to driven element
  =   Temperature of the area around the coupling (observe radiant heat)
S   =   Temperature factor
SA   =   Shock or load factor
SZ   =   Start factor (factor for the number of starts/hour)
Zh   =   Cycle of starts (1/h)


Sizing of a Servomax® or Ecolight® Elastomer Coupling

1. Calculation example without shock or reversing loads

The rated torque of the coupling (TKN) needs to be higher than the rated torque of the driven element (TLN) times the temperature factor S at the coupling for the application. If TLN is not known, TAN can be used for the calculation instead.

Condition:       Auxiliary calculation:

Calculation example: (No loads and shocks)

Drive face: DC - motor
              TAN = 119 Nm
Coupling conditons:
= 70° C
S = 1,7 (for 70°/Type A))
Driven face: Pump
TLN = 85 Nm
     
Bedingung: TKN > TLN x S
TKN > 85 Nm x 1,7
TKN > 144,5 Nm
Result: A coupling type EK 2/150/A (TKN = 160 Nm) is selected.

2. Calculation example with shock loads

In all cases the maximum rated torque (TKmax). of the coupling can not be exceeded. First calculate the rated torque (TKN) of the coupling same as above. Compare this result to the peak torque (TS) times the start factor (SZ ) times the temperature factor (SU ) for the application. The greater of the two values must be less than (TKmax) of the coupling.

Condition:       Auxiliary calculation:

Condition:       Auxiliary calculation: